Latex Examination Glove is used as a good biological barrier to protect the user’s hands against contamination. An all-rounder glove that is suitable for use in medical healthcare and dental procedures. It’s elastic and soft latex film provides superior dexterity with good fit & tactile sensitivity. The evenly distributed lightly powdered at the donning side makes this glove so easy to don and is effective for perspiration absorption which provide comfortable and dry feel.
- European Countries: Class I EU MDR 2017/745
- United States of America (USA): Class I

Product Specification
- MaterialNatural High Grade Rubber Latex
- TypePowdered, Non-Sterile
- Design & FeaturesSmooth or Palm Textured Surface, Ambidextrous, Beaded cuff, USP Grade Absorbable Corn Starch
- ColourNatural, Blue, Green
- FlavourNon-flavoured or Flavoured [Vanilla or Mint]
- Shelf-life5 years from the date of manufacturing
- StorageThe gloves shall maintain their properties when stored in a dry condition. Avoid direct sunlight
- ApplicationMedical, Healthcare, Dental
Quality Performance
Functional Benefits
- A good barrier protection against bacteria and viruses
- Superior dexterity & flexibility
- Good fit & tactile sensitivity
- Latex softness provide comfortability for extended use
- Lightly powdered interior promote easy donning & doffing and is effective for perspiration absorption
Glove Sizes
- XS
- S
- M
- L
- XL
Quality Standards
- Manufactured under QSR (GMP), ISO 9001:2015 and ISO 13485:2016 Quality Management System
- Conforms to ASTM D3578, EN455, ISO 11193 Standards
- Complied to PPE Regulation (EU) 2016/425 requirements

Physical Dimension & Physical Properties
DN GLOVE
Size | Length (mm) | Palm width (mm) | Thickness : Single wall (mm) |
---|---|---|---|
XSSMLXL | Min 230, Min 240(All sizes) | 76 ± 384 ± 394 ± 3105 ± 3113 ± 3 | Finger : Min 0.08 (≥ 3.2 Mil)Palm : Min 0.08 (≥ 3.2 Mil) |
ASTM D3578
Size | Length (mm) | Palm width (mm) | Thickness : Single wall (mm) |
---|---|---|---|
XSSMLXL | Min 220 (XS, S)Min 230 (M, L, XL) | 70 ± 1080 ± 1095 ± 10111 ± 10120 ± 10 | Finger: Min 0.08 (≥ 3.2 Mil)Palm : Min 0.08 (≥ 3.2 Mil) |
Elongation at Break, %
- Before Aging Min 650
- After Aging Min 500
Tensile Strength, MPa
- Before Aging Min 18
- After Aging Min 14
EN 455
Size | Length (mm) | Palm width (mm) | Thickness : Single wall (mm) |
---|---|---|---|
XSSMLXL | Min 240 | ≤8080 ± 1095 ± 10110 ± 10≥110 | N/A |
Median Force at Break, N
- Before Aging Min 6
- After Aging Min 6
ISO 11193
Size | Length (mm) | Palm width (mm) | Thickness : Single wall (mm) |
---|---|---|---|
XSSMLXL | Min 220 (XS, S)Min 230 (M, L, XL) | ≤8080 ± 1095 ± 10110 ± 10≥110 | Smooth : Min 0.08 (≥ 3.2 Mil)Textured : Min 0.11 (≥ 4.4 Mil) |
Elongation at Break, %
- Before Aging Min 650
- After Aging Min 500
Median Force at Break, N
- Before Aging Min 7
- After Aging Min 6
Product Safety Conformance
CHEMICAL RESIDUE TESTED Pass
Purpose: To ensure the gloves are free from any chemical substances and safe to use.
Chemical Test (s) | Test Results (μg/g) |
---|---|
Butylated Hydroxyanisole (BHA) | Not Detected |
Butylated Hydroxytoluene (BHT) | Not Detected |
Diphenyl Guanidine (DPG) | Not Detected |
Diphenyl Thiourea (DPT) | Not Detected |
Mercaptobenzothiazole (MBT) | Not Detected |
Tetramethylthiuram Disulphide (TMTD) | Not Detected |
Zinc Dibutyldithiocarbamate (ZDBC) | Not Detected |
Zinc Diethyldithiocarbamate (ZDEC) | Not Detected |
Zinc Dimethyldithiocarbamate (ZDMC) | Not Detected |
Zinc Mercaptobenzimidazole (ZMBI) | Not Detected |
Zinc Mercaptobenzothiazole (ZMBT) | Not Detected |
Zinc Pentamethyleneditithiocarbamate (ZPMC) | Not Detected |
Remark: Applicable to selected product. Please liaise with our representative for further details.
VIRAL PENETRATION TESTED Pass
Reference: ASTM F1671 – Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Blood – Borne Pathogens Using Phl-X 174 Bacteriophage Penetration as a Test System
Purpose: To test the barrier protection of the gloves from the passages of the viruses.
Viral Penetration | Test Results |
---|---|
PASSES |
Remark: Applicable to selected products. Please liaise with our representative for further details.
BIOCOMPATIBILITY TESTED Pass
Reference: ISO 10993-10 (Test for Skin Irritation and Skin Sensitization)
Purpose: Biological evaluation for medical devices for irritation and delayed type hypersensitivity.
Biocompatibility Test | Test Results |
---|---|
Primary Skin Irritation | PASSESNot a primary skin irritant under condition of the study |
Skin Sensitization | PASSESNot a contact sensitizer under condition of the study |
Remark: Applicable to selected product. Please liaise with our representative for further details.
HEAVY METAL TESTED Pass
Reference: EPA Method 3052
Purpose: To ensure the gloves are free from heavy metal substances and safe to use.
Chemical Test (s) | Test Results (μg/g) |
---|---|
Cadmium (Cd) | Not Detected |
Lead (Pb) | Not Detected |
Mercury (Hg) | Not Detected |
Arsenic (As) | Not Detected |
Antimony (Sb) | Not Detected |
Tin (Sm) | Not Detected |
Remark: Applicable to selected product. Please liaise with our representative for further details.
PHTHALATES TESTED Pass
Purpose: Compliance on REACH Regulation (EC) 1907/2006 Annex XVII requirements for phthalates
Chemical Test (s) | Test Results (μg/g) |
---|---|
Dibutyl Phthalate (DBP) | Not Detected |
Di(2-ethylhexyl) Phthalate (DEHP) | Not Detected |
Di-n-octyl Phthalate (DNOP) | Not Detected |
Di-isononyl Phthalate (DINP) | Not Detected |
Di-isodecyl Phthalate (DIDP) | Not Detected |
Benzyl butyl Phthalate (BBP) | Not Detected |
Remark: Applicable to selected product. Please liaise with our representative for further details.